- RadiForce R31
R31 and R31-C 3MP color LCD monitors offer high resolution and high luminance for accurate display of color and grayscale MRI, PET and CR images. Ideal for 3D color rendering and image fusion display.
DICOM Part 14 Compliant
To ensure the most accurate and consistent shadings possible, EIZO carefully measures and sets every grayscale tones on the production line to produce a monitor compliant with DICOM Part 14.
DICOM Part 14 Calibration
When the self-diagnosis function, utilized with bundled RadiCS LE quality control software, detects a change in luminance, a warning icon appears on the desktop taskbar enabling prompt correction. Furthermore, the self-calibration function, a simplified calibration compliant with the DICOM Part 14 standard, can periodically be performed to correct the grayscale tones and brightness of the monitor.
10-bit Color Input Support

Each color (RGB) is supported with a 10-bit input compatibility that displays up-to 1,064,330,000 colors, providing highly-crisp resolution for 3D color rendering and image fusion.
10-bit color graphics board and 10-bit color viewer software needed for 10-bit color display.
Dual Link Input Support

With dual link input support, monitors achieved a clock frequency of 60 Hz even when displaying QXGA (1536 x 2048) resolution. This enables frame synchronization between the computer and the monitor, which reproduces a smooth moving picture without any dropping of frames.
Graphics board with dual link compatibility required.
Calibration Mode Selection
Selectable with the front panel buttons, the CAL Switch function allows for various calibration modes of different modalities such as CR, CT, and endoscope images. Furthermore, auto mode settings can be made with the Auto CAL Switch function.
Image Rotation
The Image Rotation function offers hardware-based switching between portrait and landscape mode. This eliminates the need for special software and does not compromise graphics performance.
Brightness Stabilization
At startup or upon wakeup, the EIZO patented drift correction function quickly stabilizes the brightness level. In addition, a sensor measures the backlight brightness and compensates for brightness fluctuations caused by the ambient temperature and the passage of time.
This brightness stabilization function is EIZO patented technology (Japan patent numbers 3171808 and 3193315, US patent number 6188380).
Wide Viewing Angles
Wide Viewing angles with minimal color shift when viewed from the side.
Backlight Saver with Screen Saver
With ScreenManager Pro for Medical utility software installed, the Backlight Saver function turns off the monitor’s backlight when the screen saver is activated, and turns it on again when the computer comes out of screen saver mode. This function helps to reduce power consumption when the monitor is used for a prolonged period of time.
Backlight Saver with Viewer Application
By setting the Backlight Saver function to operate with viewer application, the monitor’s backlight is on while the viewer is being used and the backlight is off while the viewer is not being used.
Ergonomic Design
Narrow bezels require less eye movement in a multi-panel environment. The height and pivot adjustable stand offers added flexibility and viewing comfort.
LCD Panel Protector
This anti-reflective panel protector is pre-attached to the monitor at production for protection against dust and scratches.
Full 3-Year Warranty
EIZO and its authorized distributors offer a three-year limited warranty.
Brightness Stability Within Usage Time Guaranteed
EIZO's confidence in its product quality extends to brightness stability which is also covered during the usage time specified in the warranty.
Customer Assurance
Meets the strictest medical, safety and EMC emissions standards including TÜV/GM, UL60601-1, CE, CB, CSA C22.2 No.601-1, VCCI, FCC, and FDA 510(k).
ISO 13485 Certification
Acquiring ISO 13485 certification demonstrates EIZO's ability to consistently meet customer requirements for these devices and services.
| Model | RadiForce R31: without Panel Protector RadiForce R31-C: with Panel Protector |
|
|---|---|---|
| Cabinet Color | Black | |
| Panel | 53 cm (20.8") TFT Color LCD Panel (IPS) | |
| Active Display Size (H x V) | 318.0 x 423.9 mm | |
| Viewable Image Size | Diagonal: 529 mm | |
| Native Resolution | 1536 x 2048 | |
| Pixel Pitch | 0.207 x 0.207 mm | |
| Display Colors | 10-bit colors: 1.06 billion (maximum) colors 8-bit colors: 16.77 million from a palette of 1.06 billion colors |
|
| Viewing Angles (H, V) | 170°, 170° | |
| Brightness | R31: 400 cd/m2, R31-C: 350 cd/m2 | |
| Recommended Brightness for Calibration | R31: 250 cd/m2, R31-C: 220 cd/m2 | |
| Contrast Ratio | 400:1 | |
| On/Off Response Time | 50 ms (typical) | |
| Scanning Frequency (H, V) | 31 - 127 kHz, 59 - 61 Hz (VGA Text: 69 - 71 Hz, QXGA: 36 - 61 Hz) Frame synchronous mode: 59 - 61 Hz |
|
| Dot Clock | 215 MHz | |
| Input Terminals | DVI-D 24 pin | |
| USB Ports | 1 upstream, 2 downstream | |
| USB Standard | Rev. 2.0 | |
| Power Requirements | AC 100 - 120 V, 200 - 240 V: 50 / 60 Hz | |
| Power Consumption / Save Mode | 110 W / Less than 3 W | |
| Sensor | Backlight Sensor | |
| Power Management | DVI DMPM | |
| OSD Languages | English, German, French, Italian, Japanese, Spanish, Swedish | |
| Net Weight (With Stand / Without Stand) | R31 9.2 kg, R31-C 10.0 kg / R31 6.2 kg, R31-C 7.0 kg |
|
| Hole Spacing | VESA standard 100 x 100 mm | |
| Certifications and Standards | CE (Medical Device Directive), TÜV/GM (EN60601-1), cTÜVus (UL60601-1, CSA C22.2 No. 601-1), CB (IEC60601-1), VCCI-B, FCC-B, Canadian ICES-003-B, FDA 510(k)*, CCC, EIZO Eco Products 2002, RoHS | |
| Supplied Accessories | AC power cord, user's manual, dual link signal cable (DVI-D ~ DVI-D), USB cable, EIZO LCD Utility Disk (RadiCS LE, ScreenManager Pro for Medical), ScreenCleaner (R31-C only), warranty card | |
| Warranty | Three Years |
| * Display of mammography images for diagnosis is not supported. |